Distribution Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV)
Mga Teknikal na Parameter:
| Fanout Panloob na Fiber Optical Cable (GJFJV) | Diametro ng kable | Timbang | |
| 2 core | 4.5mm | 22.00kg/km | |
| 4 na core | 4.5mm | 22.00kg/km | |
| 6 na core | 4.5mm | 23.00kg/km | |
| 8 core | 5.5mm | 27.00kg/km | |
| 10 core | 5.5mm | 30.00kg/km | |
| 12 core | 6.0mm | 35.00kg/km | |
| Temperatura ng imbakan (℃) | -20+60 | ||
| Minimum na Radius ng Pagbaluktot (mm) | Pangmatagalan | 10D | |
| Minimum na Radius ng Pagbaluktot (mm) | Panandaliang termino | 20D | |
| Pinakamababang pinapayagang Lakas ng Tensile (N) | Pangmatagalan | 200 | |
| Pinakamababang pinapayagang Lakas ng Tensile (N) | Panandaliang termino | 600 | |
| Karga ng Pagdurog (N/100mm) | Pangmatagalan | 200 | |
| Karga ng Pagdurog (N/100mm) | panandaliang panahon | 1000 | |
Katangian ng hibla:
| Istilo ng hibla | Yunit | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| kundisyon | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| pagpapahina | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Pagkakalat | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Bandwidth | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Sero na haba ng daluyong na dispersyon | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Zero dispersion slope | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| PMD Pinakamataas na Indibidwal na Hibla | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Halaga ng Link sa Disenyo ng PMD | Ps(nm2*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Daloy ng haba ng hibla na cutoff λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Pagputol ng kablehaba ng daluyong λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| NumerikalApertura (NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Hakbang (mean ng bidirectionalpagsukat) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Mga iregularidad sa hiblahaba at punto | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Pagkakahiwalay | |||||||||
| Pagkakaiba ng backscatterkoepisyent | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Pagkakapareho ng pagpapalambing | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Diametro ng core | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Diametro ng pambalot | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Hindi pabilog na cladding | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Diametro ng patong | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Patong/chaffinchkonsentrikong error | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Hindi pabilog na patong | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Error sa konsentrisidad ng core/cladding | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Kulot (radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Mga Konstruksyon ng Kable:
Pagputol ng Kable:
Multimode OM3 8 core na Kable
Single mode 4 cores na kable
Multimode 50/125 24 cores na Kable
Mga Paglalarawan:
•Ang Distribution Fanout Tight Buffer Indoor Fiber Optical Cable ay gumagamit ng 2~48 core (o higit pa) na may 900μm o 600μm tight buffer fiber bilang optical sub cable. Karaniwan itong gumagamit ng PVC o LSZH, PE o Nilon din.
•Ang masikip na buffer fiber ay binabalot ng isang patong ng aramid yarn bilang matibay na bahagi, pagkatapos ay kinukumpleto ng isang patong ng PVC o LSZH na materyal bilang panlabas na sako.
•Ang kulay ng out jacket ng Distribution Fanout Tight Buffer Indoor Fiber Optical Cable:
Iisang mode: Dilaw,
Multimode OM1 / OM2: Kahel,
Multimode OM3 / OM4: Tubig,
Multimode OM4: Lila,
Mutimode OM5: Dayap.
Opsyonal ang ibang kulay.
Aplikasyon:
+ Ginagamit sa mga pigtail at patch cord.
+ Ginagamit bilang mga linya ng pagkakabit ng mga kagamitan, at ginagamit sa mga koneksyong optikal sa mga kagamitang optikalmga silid ng komunikasyon, sentro ng datos at mga frame ng pamamahagi ng optika.
+ Ginagamit sa mga kable sa loob ng bahay, lalo na bilang kable ng distribusyon.
Mga Katangian:
•Magandang mekanikal at pangkapaligiran na katangian.
•Ang mga katangian ng flame retardant ay nakakatugon sa mga kinakailangan ng mga kaugnay na pamantayan.
•Ang mga mekanikal na katangian ng jacked ay nakakatugon sa mga kinakailangan ng mga kaugnay na pamantayan.
•Malambot, nababaluktot, madaling ilatag at pagdugtungin, at may malaking kapasidad ng pagpapadala ng data.
•Matugunan ang iba't ibang pangangailangan ng merkado at mga kliyente.
Aplikasyon: ginagamit para sa panloob na cable fan-out multi fibers pigtail/ patch cord
+ Ginagamit sa mga pigtail at patch cord.
+ Ginagamit bilang mga linya ng pagkakabit ng mga kagamitan, at ginagamit sa mga koneksyong optikal sa mga kagamitang optikal
mga silid ng komunikasyon at mga frame ng pamamahagi ng optika.
+ Ginagamit sa panloob na paglalagay ng kable, lalo na bilang distribution cable.
Pag-iimpake: