SM Single Mode G652D GYTA 24fibers Direktang Paglilibing Panlabas na Fiber Optical Cable
Teknikal na Datos ng Kable ng GYTA
| Uri ng Kable | Bilang ng Hibla | Mga Tubo | Mga Pampuno | Diametro ng Kable mm | Timbang ng Kable kg/km | Lakas ng Pag-igting Pangmatagalan/Pangmaikliang Panahon N | Paglaban sa Pagdurog Pangmatagalan/Pangmaikli N/100mm | Radius ng Pagbaluktot Estatiko mm |
| GYTA-2~12 | 8~12 | 1 | 4 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-14~18 | 14~18 | 3 | 2 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-20~24 | 20~24 | 4 | 1 | 9.5 | 110 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-26~36 | 26~36 | 4 | 1 | 9.5 | 120 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-38~48 | 38~48 | 4 | 1 | 10.0 | 140 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-50~60 | 50~60 | 5 | 0 | 10.8 | 150 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-62~72 | 62~72 | 6 | 0 | 11.9 | 170 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-74~84 | 74~84 | 7 | 1 | 12.5 | 180 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-86~96 | 86~96 | 8 | 0 | 13.6 | 210 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-98~108 | 98~108 | 9 | 1 | 14.5 | 230 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-110~120 | 110~120 | 10 | 0 | 14.8 | 240 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTS-122~144 | 122~132 | 11 | 1 | 15.4 | 260 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-146~216 | 146~216 | 12 | 0 | 19.8 | 395 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-218~288 | 218~288 | 12 | 0 | 20.8 | 470 | 1000/3000 | 1000/3000 | 10D/20D |
Katangian ng hibla:
| Istilo ng hibla | Yunit | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Kundisyon | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Pagpapahina | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Pagkakalat | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Bandwidth | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Sero na haba ng daluyong na dispersyon | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Zero dispersion slope | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| PMD Pinakamataas na Indibidwal na Hibla | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Halaga ng Link sa Disenyo ng PMD | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Daloy ng haba ng hibla na cutoff λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Pagputol ng kable haba ng daluyong λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numerikal Apertura (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Hakbang (mean ng bidirectional pagsukat) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Mga iregularidad sa haba at punto ng hibla | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Pagkakaiba ng backscatter koepisyent | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Pagkakapareho ng pagpapalambing | dB/km | ≤0.01 | ≤0.01 | |||||
| Diametro ng core | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Diametro ng pambalot | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Hindi pabilog na cladding | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Diametro ng patong | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Patong/chaffinch konsentrikong error | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Hindi pabilog na patong | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Error sa konsentrisidad ng core/cladding | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Kulot (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Kulay ng hibla:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Asul | Kahel | Berde | Kayumanggi | Kulay abo | Puti |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Pula | Itim | Dilaw | Lila | Rosas | Tubig |
Paglalarawan ng Kable ng GYTA
+ Ang mga hibla, 250μm, ay nakaposisyon sa isang maluwag na tubo na gawa sa high modulus plastic.
+ Ang mga tubo ay puno ng panlinis na hindi tinatablan ng tubig.
+ Isang alambreng bakal, na minsan ay nababalutan ng polyethylene (PE) para sa kable na may mataas na bilang ng hibla, ang matatagpuan sa gitna ng core bilang isang bahaging may lakas na metal.
+ Ang mga tubo (at mga tagapuno) ay nakakabit sa paligid ng strength member patungo sa isang siksik at pabilog na cable core.
+ IsangAluminyo Polyethylene Laminate (APL)ay inilalapat sa paligid ng core ng kable, na pinupuno ng filling compound upang protektahan ito mula sa pagpasok ng tubig.
+ Ang kable ay kinumpleto ng PE sheath.
Konstruksyon:
Mga Katangian ng GYTA Cable:
+ Magandang mekanikal at temperaturang pagganap
+ Mataas na lakas na maluwag na tubo na lumalaban sa hydrolysis
+ Tinitiyak ng espesyal na compound ng pagpuno ng tubo ang kritikal na proteksyon ng hibla
+ Ang espesyal na dinisenyong siksik na istraktura ay mahusay sa pagpigil sa pagliit ng mga maluwag na tubo
+ Pinoprotektahan ng PE sheath ang kable mula sa ultraviolet radiation
+ Ang mga sumusunod na hakbang ay ginagawa upang matiyak na hindi tinatablan ng tubig ang kable:
+ Kawad na bakal na ginagamit bilang pangunahing bahagi ng lakas
+ Maluwag na tambalang pagpuno ng tubo
+ 100% pagpuno ng core ng kable
+ 100% sinubukan bago ipadala.
+ Haba ng reel ng kable: 1km, 2km, 3km, 5km
Aplikasyon ng GYTA Cable:
+ Ginagamit sa pamamahagi sa labas.
+ Angkop para sa paglalagay ng tubo, direktang paglilibing, at pamamaraan sa ilalim ng lupa.
+ Komunikasyon sa malayuan at lokal na network.
Pag-iimpake: