Single Mode Central Loose Tube GYXTW Aerial Outdoor Optical Fiber Cable
Mekanikal na Katangian ng GYXTW Fiber Optic Cable:
| Kable ng GYXTW | Diametro ng kable | Timbang |
| Bilang ng hibla: 2 hibla hanggang 24 na hibla | 8.0mm+-0.5mm | 70kg/km |
| 7.0mm+-0.3mm | 50kg/km | |
| Saklaw ng temperatura | -40°C+70°C | |
| Minimum na Radius ng Pagbaluktot (mm) | Pangmatagalan | 10D |
| Minutong PagbaluktotRadius (mm) | Panandaliang termino | 20D |
| Pinakamababang pinapayagang Lakas ng Tensile (N) | Pangmatagalan | 1200 |
| Pinakamababang pinapayagang Lakas ng Tensile (N) | Panandaliang termino | 1500 |
| Temperatura ng operasyon | -40°C+70°C | |
| Temperatura ng pag-install | -20°C+60°C | |
| Temperatura ng imbakan | -40°C+70°C | |
Katangian ng hibla:
| Istilo ng hibla | Yunit | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Kundisyon | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Pagpapahina | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Pagkakalat | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Bandwidth | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Sero na haba ng daluyong na dispersyon | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Zero dispersion slope | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| PMD Pinakamataas na Indibidwal na Hibla | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Halaga ng Link sa Disenyo ng PMD | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Daloy ng haba ng hibla na cutoff λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Pagputol ng kable haba ng daluyong λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numerikal Apertura (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Hakbang (mean ng bidirectional pagsukat) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Mga iregularidad sa haba at punto ng hibla | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Pagkakaiba ng backscatter koepisyent | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Pagkakapareho ng pagpapalambing | dB/km | ≤0.01 | ≤0.01 | |||||
| Diametro ng core | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Diametro ng pambalot | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Hindi pabilog na cladding | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Diametro ng patong | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Patong/chaffinch konsentrikong error | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Hindi pabilog na patong | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Error sa konsentrisidad ng core/cladding | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Kulot (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Kulay ng hibla:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Asul | Kahel | Berde | Kayumanggi | Kulay abo | Puti |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Pula | Itim | Dilaw | Lila | Rosas | Tubig |
Ano ang kable ng GYXTW?
•Ang GYXTW fiber optic cable, na may habang 250μm, ay nakaposisyon sa isang maluwag na tubo na gawa sa high modulus plastic.
•Ang mga tubo ay puno ng isang compound na hindi tinatablan ng tubig.
•Ang tubo ay nakabalot ng isang patong ng PSP nang pahaba.
•Sa pagitan ng PSP at ng maluwag na tubo na nakaharang sa tubig ay inilalagay ang materyal upang mapanatiling siksik at hindi tinatablan ng tubig ang kable.
•Dalawang magkahilera na alambreng bakal ang inilalagay sa magkabilang gilid ng teyp na bakal.
•Ang kable ay kinumpleto ng isang polyethylene (PE) sheath, kulay itim, upang protektahan ang hibla mula sa UV.
Konstruksyon:
Mga Katangian:
•Parallel member na gawa sa steel-wire, nakabaluti ang filler protect tube na gawa sa fiber steel tape.
•Napakahusay na mekanikal at pangkapaligiran na pagganap.
•Compact na istraktura, magaan ang timbang ay maaaring mai-install nang maginhawa at madaling patakbuhin.
•May iba pang opsyon na magagamit para sa fiber: Single mode (G652D, G657A, G657B) at Multimode (OM1, Om2, Om3, OM4, OM5)
•Bilang ng hibla: 2fo ~ 12fo
•Pagpipilian sa diyametro: 6.0mm, 7.0mm (ex-work), 8.0mm
Aplikasyon:
+ Ginagamit sa pamamahagi sa labas.
+ Angkop para sa aerial, paraan ng paglalagay ng pipeline.
+ Komunikasyon sa malayuan at lokal na network.
Pag-iimpake: