Distribution Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV)
Mga Teknikal na Parameter:
| Fanout Indoor Fiber Optical Cable (GJFJV) | Diametro ng cable | Timbang | |
| 2 core | 4.5mm | 22.00kg/km | |
| 4 na core | 4.5mm | 22.00kg/km | |
| 6 na core | 4.5mm | 23.00kg/km | |
| 8 core | 5.5mm | 27.00kg/km | |
| 10 core | 5.5mm | 30.00kg/km | |
| 12 core | 6.0mm | 35.00kg/km | |
| Temperatura ng imbakan (℃) | -20+60 | ||
| Min Bending Radius(mm) | Pangmatagalan | 10D | |
| Min Bending Radius(mm) | Maikling termino | 20D | |
| Min na pinapayagang Tensile Strength(N) | Pangmatagalan | 200 | |
| Min na pinapayagang Tensile Strength(N) | Maikling termino | 600 | |
| Crush Load (N/100mm) | Pangmatagalan | 200 | |
| Crush Load (N/100mm) | panandalian | 1000 | |
Katangian ng hibla:
| Estilo ng hibla | Yunit | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| kundisyon | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| pagpapalambing | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Pagpapakalat | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Bandwidth | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Zero dispersion wavelength | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Zero dispersion slope | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| PMD Maximum Individual Fiber | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Halaga ng Link ng Disenyo ng PMD | Ps(nm2*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Fiber cutoff wavelength λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Cable cutoffhaba ng daluyong λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| NumericalAperture(NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Hakbang(mean ng bidirectionalpagsukat) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Mga iregularidad sa hiblahaba at punto | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Kawalan ng pagpapatuloy | |||||||||
| Pagkakaiba backscatterkoepisyent | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Pagkakatulad ng pagpapalambing | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Core diameter | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Diametro ng cladding | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Diametro ng patong | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Patong/chaffinchconcentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Error sa core/cladding concentricity | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Curl(radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Mga Konstruksyon ng Cable:
Cable Cut-Out:
Multimode OM3 8 core Cable
Single mode 4 core Cable
Multimode 50/125 24 core Cable
Mga paglalarawan:
•Ang Distribution Fanout Tight Buffer Indoor Fiber Optical Cable ay gumagamit ng 2~48 core (o higit pa) ay gumagamit ng 900μm o 600μm tight buffer fiber bilang optical sub cable. Karaniwan itong sumasakop sa paggamit ng PVC o LSZH, gumamit din ng PE o Nilon.
•Ang masikip na buffer fiber na binalot ng isang layer ng aramid yarn bilang strength member, pagkatapos ay kinumpleto ng isang layer ng PVC o LSZH material bilang out jacket.
•Ang Distribution Fanout Tight Buffer Indoor Fiber Optical Cable out na kulay ng jacket:
Single mode: Dilaw,
Multimode OM1 / OM2: Orange,
Multimode OM3 / OM4: Aqua,
Multimode OM4: Violet,
Mutimode OM5: Lime.
Opsyonal ang ibang kulay.
Application:
+ Ginagamit sa pigtails at patch cords.
+ Ginagamit bilang magkabit na linya ng mga kagamitan, at ginagamit sa optical na koneksyon sa opticalmga silid ng komunikasyon, data center at optical distribution frame.
+ Ginagamit sa panloob na paglalagay ng kable, lalo na ginagamit bilang kable ng pamamahagi.
Mga katangian:
•Magandang mekanikal at kapaligiran na mga katangian.
•Ang mga katangian ng flame retardant ay nakakatugon sa mga kinakailangan ng mga nauugnay na pamantayan.
•Ang mga mekanikal na katangian ng jacked ay nakakatugon sa mga kinakailangan ng mga nauugnay na pamantayan.
•Malambot, nababaluktot, madaling ilagay at dugtungan, at may malaking kapasidad na paghahatid ng data.
•Matugunan ang iba't ibang mga kinakailangan ng merkado at mga kliyente.
Application: ginagamit para sa panloob na cable fan-out multi fibers pigtail/ patch cord
+ Ginagamit sa pigtails at patch cords.
+ Ginagamit bilang magkabit na linya ng mga kagamitan, at ginagamit sa optical na koneksyon sa optical
mga silid ng komunikasyon at optical distribution frame.
+ Ginamit sa panloob na paglalagay ng kable, lalo na ginagamit bilang pamamahagi ng cable.
Pag-iimpake: